60D6h, 68D6h Touch probe 1 negative edge counter - AxisX
A counter that is incremented with each falling edge of the touch probe 1 input.
The counter is only valid if the touch probe 1 is enabled (60B8h, bit 0 = 1b). When configured to capture only the first event only bit 0 changes. When configured for continuous triggering, the value is an unsigned 16-bit value with overflow.
See Touch Probes.
Axis 1
Parameter | Index | Sub-Index | Data Type | Float Scale | Units | Access | PDO Mappable | SMM Versions |
---|---|---|---|---|---|---|---|---|
Touch probe 1 negative edge counter - Axis 1 | 60D6h | 0 | Unsigned16 | - | - | Read only | Yes | All |
Axis 2
Parameter | Index | Sub-Index | Data Type | Float Scale | Units | Access | PDO Mappable | SMM Versions |
---|---|---|---|---|---|---|---|---|
Touch probe 1 negative edge counter - Axis 2 | 68D6h | 0 | Unsigned16 | - | - | Read only | Yes | All |